Din En 60352-2 Pdf |best| Guide
The Case of the Intermittent Dashboard
Act 1: The Failure
- Tooling Wear: How dies wear out over time and affect crimp height.
- Wire Quality: The effect of wire strand count, plating (tin vs. silver vs. nickel), and temper.
- Terminal Design: How the barrel design of the contact influences the mechanical grip.
2. Tensile (Pull-Out) Force
Clause 6 of the standard specifies the minimum pull-out force for a given conductor cross-section (e.g., 0.20 mm², 0.50 mm², 1.50 mm²). A tensile test machine must pull the wire axially from the terminal until failure. din en 60352-2 pdf
), industry professionals often refer to alternative standards like NF F 61-030. Key Requirements of DIN EN 60352-2 The Case of the Intermittent Dashboard Act 1: The Failure
The standard defines several tests to validate the quality of the connection: Tooling Wear: How dies wear out over time
- Sample preparation and testing
- Test conditions and test sequences
- Criteria for acceptance or rejection
- Type Tests (Qualification): Performed on sample batches to prove the design works.
Pro Tip: If you only need to look up crimp height or pull force for a specific wire size, check if your tooling manufacturer (e.g., Weidmüller, Phoenix Contact, TE Connectivity) has reproduced those specific tables in their application tooling guides. They often do this with permission from DIN, legally.
Step 1 – Gap Analysis
Compare your current crimp specifications (crimp height, pull force, tool change intervals) against the standard. Document any differences.